ADAMS A1c HA-8190V set
High performance chromatography for HbA1c (gold standard)
- Correct HbA1c results even in the presence of Hb variants
- No influence of interfering factors
- Fastest HbA1c analytics
Delivery / installation will take place shortly after order confirmation
30+ years of experience
and end-to-end service from a single source – from installation to maintenance, with fast delivery and reliable support.
Further Information
HPLC is the fastest, most precise and cheapest method for HbA1c analysis to reliably detect abnormal Haemoglobins and to get a correct HbA1c-result..
- Highest precision
- Low CV < 1%
- Seamless mode switching between FM/VM
- No column-bound reagents
- Cap Piercing - pipetted from closed primary tubes
- Hemolysed capillary blood samples measurable without device changeover
Highly efficient HbA1c analysis for therapy and diagnosis using HPLC (reference method) with highest precision (VK<1%) in only 24 seconds.
- Ideally suited for high throughput - in fast mode only 24 seconds and in variant mode only 58 seconds per finding.
- No interference of the most common Hb variants HbC, HbS, HbD and HbE.
- Indication of the Hb variant on the report and output of a correct HbA1c result.
- No interference with carbamylated samples and elevated HbF values.
- Seamless mode switching FM/VM by LIS, custom rack, touch screen or middleware
- High quality column separation
- Can process EDTA but also heparin and NaF samples
- Hemolysed capillary blood samples can be measured without change of instrument setting
- Cap piercing - pipettes from closed primary tubes
- STAT mode - special single sample holder allows easy measurement of an emergency sample during rack operation
- Pipets only approx. 8 μL whole blood - no pre-dilution or haemolysis necessary
- Unique stirring-mixing function for even more precise results directly in mmol/mol (according to IFCC definition)
- Time saving as no barcode label alignment is necessary
- Eluent change possible during sample measurement/operation
- No column bound reagents. Reagents can be changed at any time, independent of batch assignment.
- Operator management system (registration of operator ID, authorised system access, printing and recording of operator name/ID on test result)
- Colour touch screen display
- Loading capacity of 100 sample tubes - expandable to 200 samples with the Side Sampler
- Calibration only required once (simultaneously in Fast Mode and Variant Mode)
- The Adams measures absolute i.e. measurement in mmol/mol (afterwards conversion in %). This is the gold standard according to IFCC
Results
Fast Mode: HbA, HbA1c, HbF
Variant Mode: HbA1c (stable HbA1c), HbF, HbA1 and detection of abnormal haemoglobin
HbS, HbC, HbD and HbE and correct HbA1c results in the presence of Hb variants
Expert opinion
Here's what our experts say about the product
Fastest HbA1c analysis by HPLC (reference method) with highest precision (CV <1%) in only 24 seconds.Expert since 2004

Jeanette Fehlmann
Related items
Available (Delivery time: 1-3 days)
Available (Delivery time: 1-3 days)
Available (Delivery time: 1-3 days)
Available (Delivery time: 1-3 days)
Washing solution for tubes for the Adams HA-8160 and Adams HA-8180.
59.00
–
+
Available (Delivery time: 1-3 days)
Sample Cup
219.00
–
+
Available (Delivery time: 1-3 days)
Haemoglobin A1c Lyophilised Controls for Adams HA-8180.
Available (Delivery time: 1-3 days)
Delivery / installation will take place shortly after order confirmation
Available (Delivery time: 1-3 days)
Available (Delivery time: 1-3 days)
This product is intended for the determination of Hemoglobin A1C (HbA1C) in human whole blood for use with ADAMSTM A1C HA-8190 series.
Available (Delivery time: 1-3 days)
You may also be interested in
6.90
–
+
Available (Delivery time: 1-3 days)
23.60
–
+
Available (Delivery time: 1-3 days)
20.00
–
+
Available (Delivery time: 1-3 days)