ACL TOP 570

Efficiency and precision - even with medium to high sample volumes.

  • Flexible in use. Strong in the portfolio.
  • Automation & Performance
  • New standards in precision and productivity
  • Item No. 12094533
  • Ref.No. 00000280047
  • Werfen
Delivery / installation will take place shortly after order confirmation

30+ years of experience

and end-to-end service from a single source – from installation to maintenance, with fast delivery and reliable support.

image

Further Information

The new ACL-TOP generation. Innovation that leads the way. Highest quality for haemostasis laboratories with medium to high throughput.
  • More reliable results thanks to validated HIL cut-off values
  • Automatic filling control for precise sample conditions
  • ACL TOP: Standardised quality, reagents and software
  • Intelligent error detection with clear user actions
  • No more manual transcription in statistics programmes
  • Access to study documentation & batch comparison report

ACL TOP 570 - High-performance haemostasis for demanding laboratories

The ACL TOP 570 system was developed for laboratories with medium to high sample volumes and combines state-of-the-art measurement technology with complete automation. It offers maximum efficiency, reliable standardisation and maximum workflow security - for routine and special diagnostics.

Technical specifications - ACL TOP 570

Measuring technology

- Coagulometric

- Chromogenic

- Immunological

Automation & Workflow

- Sample predilution

- Pre-dilution for calibration curve

- Rerun and reflex tests: configurable

- Display of the reaction curve

More efficiency through intelligent automation

- Continuous loading of samples and reagents

- Uninterrupted system operation

- Fully automated process steps from aspiration to result output

- Emergency samples can be prioritised at any time

Reliable results thanks to integrated quality checks

- Test-specific HIL check (haemolysis, icterus, lipaemia)

- Automatic fill level check

- Clot check during sample aspiration

- Autovalidation of results

High performance for high sample numbers

- Up to 240 PT tests per hour

- 80 samples onboard

- Reagents in the device:

- 24 positions in reagent racks

- 16 positions in diluent racks

- 800 cuvettes and 500 applications available

- Suitable for extensive routine and special tests

Convenient operation & consistent transparency

- Windows-based user interface

- External 22" touchscreen, keyboard and mouse

- Extensive QC tools, audit trail and electronic signature

- Complete LIS integration with bidirectional communication

Quality assurance programme

- Quality control programme: with configurable multi-rules

- Autovalidation of results

- Database for patient sample results: 2,000-20,000 samples (configurable)

- Automatic deregistration

- Logbook

- Audit trail report

Dimensions & weight

Dimensions (W × D × H): 125 × 80 × 74 cm

Weight: 148 kg

Efficient standardisation across the entire laboratory network

The uniform software, consistent reagent portfolio and identical test methodology of the ACL TOP 70 family enable standardised results - regardless of the system or location.

Expert opinion

Here's what our experts say about the product

The ACL TOP 570 impresses in routine operation with its robust automation, high throughput and integrated pre-analytical control mechanisms such as HIL check, level detection and clot detection. The consistent methodology and identical software architecture within the ACL TOP family facilitate standardisation and reduce variability. The system is technically extremely efficient for laboratories with medium to high sample volumes.
Expert since 2001
Raffael Frei
Raffael Frei

Related items

image
HemosIL SynthAFax5x 10 ml APTT / 5x 10 ml CaCl
high quality synthetic phospholipids reagent for the in vitro determination of Activated Partial Thromboplastin Time in human citrated plasma
  • Item No. 10006365
  • Ref.No. 00020007400
  • Werfen
Available (Delivery time: 2-5 days)
image
HemosIL ReadiPlasTin5x 1ml ReadiPlasTin / 5x 19ml ReadiPlasTin Diluent
ReadiPlasTin is an IVD thromboplastin reagent, based on recombinant human tissue factor, for the quantitative determination, in human citrated plasma, of Prothrombin Time on the ACL analyzers
  • Item No. 11001471
  • Ref.No. 00020301400
  • Werfen
Available (Delivery time: 2-5 days)
image
HemosIL RecombiPlasTin 2G5x 20 ml RecombiPlasTin 2G / 5x 20 ml Diluent
A high sensitivity thromboplastin reagent based on recombinant human tissue factor (RTF) for the quantitative determination in human citrated plasma of Prothrombin Time on IL Coagulation Systems
  • Item No. 10006344
  • Ref.No. 00020003050
  • Werfen
Available (Delivery time: 1-3 days)
image
HemosIL Liquid Anti-Xa5x 3 ml chromogenic substrate / 5x 2.5 ml FXa reagent
Automated chromogenic assay for the quantitative determination of unfractionated heparin (UFH) and low molecular weight heparin (LMWH) activity in human citrated plasma on IL Coagulation Systems
  • Item No. 11000177
  • Ref.No. 00020302601
  • Werfen
Available (Delivery time: 2-5 days)
image
HemosIL D-Dimer HS 5003x 4ml latex reagent/3x 6ml buffer/2x 1ml calibrator
HemosIL D-Dimer HS 500 is an automated latex enhanced immunoassay for the quantitative determination of D-Dimer in human citrated plasma on the ACL TOP® Family Systems
  • Item No. 10006622
  • Ref.No. 00020500100
  • Werfen
Available (Delivery time: 2-5 days)
image
HemosIL Q.F.A. Thrombin (Bovine)10x 2 ml
For the quantitative determination of fibrinogen, based on the Clauss method, in human citrated plasma on the IL Coagulation Systems
  • Item No. 10006516
  • Ref.No. 00020301800
  • Werfen
Available (Delivery time: 2-5 days)
image
HemosIL SynthASil5x 10 ml APTT / 5x 10 ml CaCl2
A high quality synthetic phospholipid reagent for the in vitro determination of Activated PartialThromboplastin Time (APTT)1 in human citrated plasma
  • Item No. 10006363
  • Ref.No. 00020006800
  • Werfen
Available (Delivery time: 1-3 days)

You may also be interested in

image
ACL TOP 370
With modern coagulation analysis: optimised processes, maximum performance.
Small in size, big in performance: the ACL TOP 370 system ensures fast, precise results and optimises every workflow.
  • Item No. 12086124
  • Ref.No. 00000280067
  • Werfen
Delivery / installation will take place shortly after order confirmation
image
ACL TOP 770
ACL TOP 770 for maximum performance with high sample volumes.
The new generation ACL TOP 770 offers maximum automation, high throughput and maximum process reliability - ideal for laboratories with very high sample volumes.
  • Item No. 12094629
  • Ref.No. 00000280057
  • Werfen
Delivery / installation will take place shortly after order confirmation
image
ACL TOP 550 CTS
High productivity with consistently precise results.
The ACL TOP 550 CTS offers automated coagulation diagnostics for accurate results at medium to high sample throughput.
  • Item No. 10059961
  • Ref.No. 00000280045
  • Werfen
Delivery / installation will take place shortly after order confirmation

Links

  • About us
  • What we do
  • Social Responsibility
  • Downloads
  • Jobs
  • Imprint
  • GTC
  • Support & Helpline
  • Legal Notice
  • Privacy Policy
  • Shipping & Payment conditions
  • Certificate

Go to Support Center

  • 053 33 44 90
  • Monday - Friday
  • 8 a.m. - 4p.m.
  • Go to Support Center

Contact

  • Axon Lab AG
  • Rimska ulica 4
  • SI-2310 Slovenska Bistrica
  • +386 59 33 44 90
  • info@axonlab.si

Newsletter

All prices are in EUR plus VAT and shipping costs and possibly cash on delivery charges, unless otherwise described.